HRSG (Heat Recovery Steam Generator) Structural & Mechanical Design USA & Canada

Equipment structural design - Lifting and erection methodology - Pipe stress analysis and pressure parts design - Structural steel and foundation design | Thermal power generation
We performed mandates for leaders of the industry such as Nooter Eriksen, Alstom Power and Vogt power for both mechanical design and structural design of HRSG.¬† Our main engineering tasks were:   Mechanical design:
  • Boiler external piping pipe stress analysis;
  • Pipe support design;
  • Steam drum code calculations;
  • Validation of loads at Headers and Steam drum.
  Structural design:
  • Main HRSG Casing and duct structural design;
  • Stair tower design;
  • Stack design;
  • Platforms and secondary steel design.
  • Foundation loads determination.
  3D model and drawings:
  • HRSG casing and duct 3D models, arrangement and detail drawings;
  • HRSG coil bundles 3D models, arrangement and detail drawings;
  • Stack arrangement and detail drawings;
  • Pipe support 3D models and detail drawings;
  • Platforms and secondary steel 3D models, arrangement and detail drawings.
 HyperShell Consultants were involved as a specialized engineering firm for more than 10 projects with similar scope of services for the world leaders of the industry.
  • HRSG (Heat Recovery Steam Generator) Structural & Mechanical Design Image 1